                                    低烟无卤电缆WDZ-KYJVP-52*1.5
低烟无卤电缆WDZ-KYJVP-52*1.5应用范围:

低烟无卤电缆WDZ-KYJVP-52*1.5适用于火灾报警,消防设备,排烟设备,以及紧急通道运输,照明等应急设施的供电线路中需要耐火的场所,高层建筑,宾馆,医院,地铁,核电站,隧道,发电厂,矿山,石油,化工等。

低烟无卤电缆WDZ-KYJVP-52*1.5产品结构:

导    体: 独股铜导体

线芯绝缘: 无卤交联聚烯烬

线芯颜色: 黑色编码1、2、3、4、、、、、

线芯结构: 圆形绞合

隔离材料: 玻璃纤维编织带绕包

屏    蔽: 镀锡铜丝编织

护套材料:低烟无卤护套颜色黑色

额定电压:450/750V 

低烟无卤电缆WDZ-KYJVP-52*1.5使用特性:
1、导体长期工作温度为70℃、90℃
2、电缆在750-850℃火焰条件下.可维持正常运行1.5小时以上.为B级耐火。电缆在950-1000℃火焰条件下.可维持正常运行1.5小时以上,为*耐火。
3、有毒气体含量和烟密度试验结果符合GB/T17650.2-98和GB/T17651.2-98规定
4、烟气毒性符合GAl32准安全级的要求。

生产范围:

WDZ-KYJVP-450/750V-2*0.5

WDZ-KYJVP-450/750V-6*6.0

WDZ-KYJVP-450/750V-24*0.75

WDZ-KYJVP-450/750V-2*0.75

WDZ-KYJVP-450/750V-7*0.5

WDZ-KYJVP-450/750V-24*1.0

WDZ-KYJVP-450/750V-2*1.0

WDZ-KYJVP-450/750V-7*0.75

WDZ-KYJVP-450/750V-24*1.5

WDZ-KYJVP-450/750V-2*1.5

WDZ-KYJVP-450/750V-7*1.0

WDZ-KYJVP-450/750V-24*2.5

WDZ-KYJVP-450/750V-2*2.5

WDZ-KYJVP-450/750V-7*1.5

WDZ-KYJVP-450/750V-27*0.5

WDZ-KYJVP-450/750V-2*4.0

WDZ-KYJVP-450/750V-7*2.5

WDZ-KYJVP-450/750V-27*0.75

WDZ-KYJVP-450/750V-2*6.0

WDZ-KYJVP-450/750V-7*4.0

WDZ-KYJVP-450/750V-27*1.0

WDZ-KYJVP-450/750V-3*0.5

WDZ-KYJVP-450/750V-7*6.0

WDZ-KYJVP-450/750V-27*1.5

WDZ-KYJVP-450/750V-3*0.75

WDZ-KYJVP-450/750V-8*0.5

WDZ-KYJVP-450/750V-27*2.5

WDZ-KYJVP-450/750V-3*1.0

WDZ-KYJVP-450/750V-8*0.75

WDZ-KYJVP-450/750V-30*0.5

WDZ-KYJVP-450/750V-3*1.5

WDZ-KYJVP-450/750V-8*1.0

WDZ-KYJVP-450/750V-30*0.75

WDZ-KYJVP-450/750V-3*2.5

WDZ-KYJVP-450/750V-8*1.5

WDZ-KYJVP-450/750V-30*1.0

WDZ-KYJVP-450/750V-3*4.0

WDZ-KYJVP-450/750V-8*2.5

WDZ-KYJVP-450/750V-30*1.5

WDZ-KYJVP-450/750V-3*6.0

WDZ-KYJVP-450/750V-10*0.5

WDZ-KYJVP-450/750V-30*2.5

WDZ-KYJVP-450/750V-4*0.5

WDZ-KYJVP-450/750V-10*0.75

WDZ-KYJVP-450/750V-32*0.5

WDZ-KYJVP-450/750V-4*0.75

WDZ-KYJVP-450/750V-10*1.0

WDZ-KYJVP-450/750V-32*0.75

WDZ-KYJVP-450/750V-4*1.0

WDZ-KYJVP-450/750V-10*1.5

WDZ-KYJVP-450/750V-32*1.0

WDZ-KYJVP-450/750V-4*1.5

WDZ-KYJVP-450/750V-10*2.5

WDZ-KYJVP-450/750V-32*1.5

WDZ-KYJVP-450/750V-4*2.5

WDZ-KYJVP-450/750V-12*0.5

WDZ-KYJVP-450/750V-32*2.5

WDZ-KYJVP-450/750V-4*4.0

WDZ-KYJVP-450/750V-12*0.75

WDZ-KYJVP-450/750V-36*0.5

WDZ-KYJVP-450/750V-4*6.0

WDZ-KYJVP-450/750V-12*1.0

WDZ-KYJVP-450/750V-36*0.75

WDZ-KYJVP-450/750V-5*0.5

WDZ-KYJVP-450/750V-12*1.5

WDZ-KYJVP-450/750V-36*1.0

WDZ-KYJVP-450/750V-5*0.75

WDZ-KYJVP-450/750V-12*2.5

WDZ-KYJVP-450/750V-36*1.5

WDZ-KYJVP-450/750V-5*1.0

WDZ-KYJVP-450/750V-14*0.5

WDZ-KYJVP-450/750V-36*2.5

WDZ-KYJVP-450/750V-5*1.5

WDZ-KYJVP-450/750V-14*0.75

WDZ-KYJVP-450/750V-48*0.5

WDZ-KYJVP-450/750V-5*2.5

WDZ-KYJVP-450/750V-14*1.0

WDZ-KYJVP-450/750V-48*0.75

WDZ-KYJVP-450/750V-5*4.0

WDZ-KYJVP-450/750V-14*1.5

WDZ-KYJVP-450/750V-48*1.0

WDZ-KYJVP-450/750V-5*6.0

WDZ-KYJVP-450/750V-14*2.5

WDZ-KYJVP-450/750V-48*1.5

WDZ-KYJVP-450/750V-6*0.5

WDZ-KYJVP-450/750V-19*0.5

WDZ-KYJVP-450/750V-48*2.5

WDZ-KYJVP-450/750V-6*0.75

WDZ-KYJVP-450/750V-19*0.75

WDZ-KYJVP-450/750V-52*0.5

WDZ-KYJVP-450/750V-6*1.0

WDZ-KYJVP-450/750V-19*1.0

WDZ-KYJVP-450/750V-52*0.75

WDZ-KYJVP-450/750V-6*1.5

WDZ-KYJVP-450/750V-19*1.5

WDZ-KYJVP-450/750V-52*1.0

WDZ-KYJVP-450/750V-6*2.5

WDZ-KYJVP-450/750V-19*2.5

WDZ-KYJVP-450/750V-52*1.5

WDZ-KYJVP-450/750V-6*4.0

WDZ-KYJVP-450/750V-24*0.5

WDZ-KYJVP-450/750V-52*2.5

浏览:
返回顶部