云母耐火高温电缆GNB500
产品型号:GNB500
执行标准:企业标准.
产品特性:
1、额定电压:450/750V
2、工作温度:500℃,800℃
3、导 体:裸铜或镀镍铜丝绞合
4、绝 缘:玻璃纤维+云母绕包+玻璃纤维编织
5、护 套:玻璃纤维编织+涂胶
6、颜 色:红/黄/兰/白/黑/棕/绿等
规格结构及技术参数:
芯数×截面 | 导体结构 | 绝缘厚度 | 绝缘外径 | 护套厚度 | 平均外径 | 20 ℃ 时导体 |
2 × 0.75 | 42/0.15 | 0.60 | 2.40 | 1.20 | 7.80 | 26.7 |
3 × 0.75 | 42/0.15 | 0.60 | 2.40 | 1.20 | 8.10 | 26.7 |
4 × 0.75 | 42/0.15 | 0.60 | 2.40 | 1.40 | 9.20 | 26.7 |
5 × 0.75 | 42/0.15 | 0.60 | 2.40 | 1.50 | 10.0 | 26.7 |
6 × 0.75 | 42/0.15 | 0.60 | 2.40 | 1.50 | 10.80 | 26.7 |
7 × 0.75 | 42/0.15 | 0.60 | 2.40 | 1.50 | 10.80 | 26.7 |
8 × 0.75 | 42/0.15 | 0.60 | 2.40 | 1.50 | 11.50 | 26.7 |
10 × 0.75 | 42/0.15 | 0.60 | 2.40 | 1.6 | 13.00 | 26.7 |
12 × 0.75 | 42/0.15 | 0.60 | 2.40 | 1.6 | 13.80 | 26.7 |
19 × 0.75 | 42/0.15 | 0.60 | 2.40 | 1.8 | 16.2 | 26.7 |
2 × 1 | 32/0.20 | 0.60 | 2.60 | 1.40 | 8.60 | 20.0 |
3 × 1 | 32/0.20 | 0.60 | 2.60 | 1.40 | 8.80 | 20.0 |
4 × 1 | 32/0.20 | 0.60 | 2.60 | 1.50 | 9.40 | 20.0 |
5 × 1 | 32/0.20 | 0.60 | 2.60 | 1.50 | 10.40 | 20.0 |
6 × 1 | 32/0.20 | 0.60 | 2.60 | 1.60 | 11.50 | 20.0 |
7 × 1 | 32/0.20 | 0.60 | 2.60 | 1.60 | 11.50 | 20.0 |
8 × 1 | 32/0.20 | 0.60 | 2.60 | 1.60 | 12.40 | 20.0 |
10 × 1 | 32/0.20 | 0.60 | 2.60 | 1.80 | 13.80 | 20.0 |
12 × 1 | 32/0.20 | 0.60 | 2.60 | 1.80 | 10.50 | 20.0 |
16 × 1 | 32/0.20 | 0.60 | 2.60 | 1.80 | 16.0 | 20.0 |
19 × 1 | 32/0.20 | 0.60 | 2.60 | 1.80 | 17.2 | 20.0 |
2 × 1.5 | 48/0.20 | 0.60 | 2.80 | 1.50 | 9.20 | 13.7 |
3 × 1.5 | 48/0.20 | 0.60 | 2.80 | 1.50 | 9.50 | 13.7 |
4 × 1.5 | 48/0.20 | 0.60 | 2.80 | 1.50 | 10.20 | 13.7 |
5 × 1.5 | 48/0.20 | 0.60 | 2.80 | 1.60 | 11.40 | 13.7 |
6 × 1.5 | 48/0.20 | 0.60 | 2.80 | 1.60 | 12.20 | 13.7 |
7 × 1.5 | 48/0.20 | 0.60 | 2.80 | 1.60 | 12.20 | 13.7 |
8 × 1.5 | 48/0.20 | 0.60 | 2.80 | 1.60 | 13.0 | 13.7 |
10 × 1.5 | 48/0.20 | 0.60 | 2.80 | 1.80 | 15.0 | 13.7 |
2× 2.5 | 49/0.25 | 0.70 | 3.50 | 1.60 | 10.80 | 8.21 |
3× 2.5 | 49/0.25 | 0.70 | 3.50 | 1.60 | 11.20 | 8.21 |
4× 2.5 | 49/0.25 | 0.70 | 3.50 | 1.80 | 12.60 | 8.21 |
5× 2.5 | 49/0.25 | 0.70 | 3.50 | 1.80 | 13.60 | 8.21 |
6× 2.5 | 49/0.25 | 0.70 | 3.50 | 1.80 | 14.60 | 8.21 |
7× 2.5 | 49/0.25 | 0.70 | 3.50 | 1.80 | 14.60 | 8.21 |
2× 4 | 56/0.30 | 0.70 | 4.10 | 1.60 | 12.0 | 5.09 |
3× 4 | 56/0.30 | 0.70 | 4.10 | 1.70 | 9.8 | 5.09 |
4× 4 | 56/0.30 | 0.70 | 4.10 | 1.80 | 14.0 | 5.09 |
2× 6 | 84/0.30 | 0.70 | 4.90 | 1.60 | 13.8 | 3.39 |
3× 6 | 84/0.30 | 0.70 | 4.90 | 1.80 | 14.8 | 3.39 |
4× 6 | 84/0.30 | 0.70 | 4.90 | 1.80 | 16.0 | 3.39 |